<?xml version="1.0" encoding="ISO-8859-1"?>
<?xml-stylesheet type="text/xsl" href="./fgdc_classic_fgdl.xsl"?>
<!DOCTYPE metadata SYSTEM "http://www.fgdc.gov/metadata/fgdc-std-001-1998.dtd">
<metadata>
  <idinfo>
    <citation>
      <citeinfo>
        <origin>U.S. Environmental Protection Agency</origin>
        <pubdate>20210223</pubdate>
        <title>US EPA Emissions and Generation Resource Integrated Database (EGRID 2019) for Electricity Generating Plants in Florida - Published 2021</title>
        <edition>eGRID2019 YEAR 2019 DATA</edition>
        <geoform>vector digital data</geoform>
        <pubinfo>
          <pubplace>Washington, D.C.</pubplace>
          <publish>U.S. Environmental Protection Agency</publish>
        </pubinfo>
        <othercit>State of Florida</othercit>
        <onlink>https://www.epa.gov/egrid</onlink>
      </citeinfo>
    </citation>
    <descript>
      <abstract>The Emissions &amp; Generation Resource Integrated Database (eGRID) is a comprehensive source of data on the environmental characteristics of almost all electric power generated in the United States. This dataset includes available plant-specific data for electricity generating plants in the State of Florida. The preeminent source of emissions data for the electric power sector, eGRID is based on available plant-specific data for all U.S. electricity generating plants that provide power to the electric grid and report data to the U.S. government. Data reported include, but are not limited to, net electric generation; resource mix (for renewable and nonrenewable generation); mass emissions of carbon dioxide (CO2), nitrogen oxides (NOx), sulfur dioxide (SO2), methane (CH4), nitrous oxide (N2O), and mercury (Hg); emission rates for CO2, NOx, SO2, CH4, and N2O; heat input; and nameplate capacity. eGRID reports this information on an annual basis (as well as by ozone season for NOx) at different levels of aggregation. eGRID2019, released in February 2021, is the fourteenth edition of eGRID. Please note: The EPA has recently changed the naming convention of eGRID. The current edition is named with a year corresponding to the year of the data (eGRID2019), while the publication year of the data is 2021. Those changes are reflected in the title above. For more information on eGRID please see the following EPA documentation: https://www.epa.gov/sites/production/files/2021-02/documents/egrid2019_technical_guide.pdf. This layer is an update to the FGDL layer EPAEGRID_2018.shp.  This layer is the parent for Nuclear Site, which uses the following selection: EPAEGRID.PLPRMFL = 'NUC'.</abstract>
      <purpose>The data was created to serve as base information for use in GIS systems for a variety of planning and analytical purposes.</purpose>
      <supplinf>What is eGRID? The Emissions &amp; Generation Resource Integrated Database (eGRID) is a comprehensive inventory of environmental attributes of electric power systems. The preeminent source of air emission data for the electric power sector, eGRID is based on available plant-specific data for all U.S. electricity generating plants that provide power to the electric grid and report data to the U.S. government. eGRID uses data from the Energy Information Administration (EIA) Forms EIA-860 and EIA-923 and EPA&#8217;s Clean Air Markets Program Data. Emission data from EPA are carefully integrated with generation data from EIA to produce useful values like pounds of emissions per megawatt-hour of electricity generation (lb/MWh), which allows direct comparison of the environmental attributes of electricity generation. eGRID also provides aggregated data by state, U.S. total, and by three different sets of electric grid boundaries (i.e., balancing authority area, NERC region, and eGRID subregion). Why eGRID? Many consumers have a choice regarding the source of their electricity, and some seek cleaner sources, such as wind and solar power. EPA&#8217;s Power Profiler application, which uses eGRID data, helps individual consumers understand the environmental impacts of their own electricity usage. Electricity generation is the dominant industrial source of air emissions in the United States today. Whenever you switch on an electrical appliance, chances are you are contributing to air pollution and greenhouse gas emissions. By documenting the environmental attributes of electric power generation, eGRID can help consumers and researchers to better understand the relationship between electricity and the environment. In the United States, electricity is generated in many different ways, with a wide variation in environmental impacts. In many states, power companies are required to disclose the environmental attributes of their retail electricity products. eGRID data can be used to support the following activities: Greenhouse gas registries and inventories, Carbon footprinting, Consumer information disclosure, Renewable portfolio standards, Development of emission inventories and emission standards, Analysis of changing power markets, and Estimation of avoided emissions. What information is contained in eGRID? For virtually every grid-connected power plant in the United States, eGRID provides: A detailed emissions profile, covering nitrogen oxides (NOX), sulfur dioxide (SO2), carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), and mercury (Hg). Mass emissions are reported in either pounds or tons. Output emission rates are reported pounds per megawatt-hour (lb/MWh). Input emission rates are reported in pounds per million British thermal units (lb/MMBtu). Generation resource mix, in megawatt-hours and percent. Identification and location information. eGRID provides separate data at the combustion unit and generator levels. These data are combined at the plant level. The plant level data are then aggregated to state, U.S. total, and three types of power grid regions:? Balancing authority area (generally smaller regions of the power grid in which all power plants are managed to balance power system demand and supply); eGRID subregion; and NERC region, as designated by the North American Electric Reliability Corporation (plus Alaska, Hawaii, and Puerto Rico). Source: https://www.epa.gov/egrid/egrid-questions-and-answers</supplinf>
    </descript>
    <timeperd>
      <timeinfo>
        <sngdate>
          <caldate>20190101</caldate>
        </sngdate>
      </timeinfo>
      <current>publication date</current>
    </timeperd>
    <status>
      <progress>Complete</progress>
      <update>As needed</update>
    </status>
    <spdom>
      <bounding>
        <westbc>-87.416105</westbc>
        <eastbc>-79.880562</eastbc>
        <northbc>31.424670</northbc>
        <southbc>24.526882</southbc>
      </bounding>
    </spdom>
    <keywords>
      <theme>
        <themekt>None</themekt>
        <themekey>Power</themekey>
        <themekey>power plant</themekey>
        <themekey>Emissions &amp; Generation Resource Integrated Database</themekey>
        <themekey>electric</themekey>
        <themekey>Nuclear</themekey>
        <themekey>electricity</themekey>
        <themekey>power grid</themekey>
      </theme>
      <theme>
        <themekt>ISO 19115 Topic Category</themekt>
        <themekey>environment</themekey>
        <themekey>utilitiesCommunication</themekey>
      </theme>
      <place>
        <placekt>None</placekt>
        <placekey>Florida</placekey>
      </place>
      <temporal>
        <tempkt>None</tempkt>
        <tempkey>2018</tempkey>
      </temporal>
    </keywords>
    <accconst>None</accconst>
    <useconst>The Florida Geographic Data Library is a collection of Geospatial Data compiled by the University of Florida GeoPlan Center with support from the Florida Department of Transportation. GIS data available in FGDL is collected from various state, federal, and other agencies (data sources) who are data stewards, producers, or publishers. The data available in FGDL may not be the most current version of the data offered by the data source. University of Florida GeoPlan Center makes no guarantees about the currentness of the data and suggests that data users check with the data source to see if more recent versions of the data exist. Furthermore, the GIS data available in the FGDL are provided 'as is'. The University of Florida GeoPlan Center makes no warranties, guaranties or representations as to the truth, accuracy or completeness of the data provided by the data sources. The University of Florida GeoPlan Center makes no representations or warranties about the quality or suitability of the materials, either expressly or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. The University of Florida GeoPlan Center shall not be liable for any damages suffered as a result of using, modifying, contributing or distributing the materials. A note about data scale: Scale is an important factor in data usage. Certain scale datasets are not suitable for some project, analysis, or modeling purposes. Please be sure you are using the best available data. 1:24000 scale datasets are recommended for projects that are at the county level. 1:24000 data should NOT be used for high accuracy base mapping such as property parcel boundaries. 1:100000 scale datasets are recommended for projects that are at the multi-county or regional level. 1:125000 scale datasets are recommended for projects that are at the regional or state level or larger. Vector datasets with no defined scale or accuracy should be considered suspect. Make sure you are familiar with your data before using it for projects or analysis. Every effort has been made to supply the user with data documentation. For additional information, see the References section and the Data Source Contact section of this documentation. For more information regarding scale and accuracy, see our webpage at: http://geoplan.ufl.edu/education.html</useconst>
    <ptcontac>
      <cntinfo>
        <cntorgp>
          <cntorg>U.S. Environmental Protection Agency</cntorg>
        </cntorgp>
        <cntpos>Energy and the Environment Website</cntpos>
        <cntaddr>
          <addrtype>mailing</addrtype>
          <address>1200 Pennsylvania Ave NW (MC 6202A)</address>
          <city>Washington</city>
          <state>D.C.</state>
          <postal>20460</postal>
          <country>US</country>
        </cntaddr>
        <cntemail>https://www.epa.gov/energy/forms/contact-us-about-energy-and-environment</cntemail>
        <cntinst>Contact Us About Energy and the Environment</cntinst>
      </cntinfo>
    </ptcontac>
    <datacred>EPA Clean Energy Department</datacred>
    <native>Version 6.2 (Build 9200) ; Esri ArcGIS 10.8.1.14362</native>
    <crossref>
      <citeinfo>
        <pubinfo>
          <pubplace>Washington, DC</pubplace>
          <publish>U.S. Environmental Protection Agency</publish>
        </pubinfo>
        <othercit>EPA - eGRID: https://www.epa.gov/egrid For more information on eGRID please see the following EPA documentation: https://www.epa.gov/sites/production/files/2021-02/documents/egrid2019_technical_guide.pdf</othercit>
        <onlink>https://www.epa.gov/egrid</onlink>
      </citeinfo>
    </crossref>
  </idinfo>
  <dataqual>
    <attracc>
      <attraccr>GeoPlan relied on the integrity of the attribute information within the original data.</attraccr>
    </attracc>
    <logic>This data is provided 'as is'. GeoPlan relied on the integrity of the original data layer's topology</logic>
    <complete>This data is provided 'as is' by GeoPlan and is complete to our knowledge.</complete>
    <posacc>
      <horizpa>
        <horizpar>This data is provided 'as is' and its horizontal positional accuracy has not been verified by GeoPlan</horizpar>
      </horizpa>
      <vertacc>
        <vertaccr>This data is provided 'as is' and its vertical positional accuracy has not been verified by GeoPlan</vertaccr>
      </vertacc>
    </posacc>
    <lineage>
      <srcinfo>
        <srccite>
          <citeinfo>
            <origin>U.S. Environmental Protection Agency</origin>
            <pubdate>20210223</pubdate>
            <title>Emissions &amp; Generation Resource Integrated Database (eGRID)</title>
            <edition>eGRID2019 year 2019 data</edition>
            <geoform>spreadsheet</geoform>
            <pubinfo>
              <pubplace>Washington, DC</pubplace>
              <publish>U.S. Environmental Protection Agency</publish>
            </pubinfo>
            <onlink>https://www.epa.gov/egrid</onlink>
          </citeinfo>
        </srccite>
        <srcscale>0</srcscale>
        <typesrc>onLine</typesrc>
        <srccitea>EPA</srccitea>
        <srccontr>Spatial and Attribute Information</srccontr>
      </srcinfo>
      <procstep>
        <procdesc>GeoPlan Center downloaded the EPA eGRID2019 year 2019 data in excel format from the following EPA website on 7/6/2021: https://www.epa.gov/egrid/download-data Released: 2/23/2021. Next, GeoPlan imported the eGRID2019 PLNT19 excel sheet from the eGRID2019 excel workbook into ArcMap. The PLNT19 excel workbook sheet contained 11,865 year 2019 records representing electricity generation plants. The PLNT19 excel workbook sheet was then exported from ArcMap as a Database table. Next the newly created PLNT19.DBF was spatially mapped using the LAT and LON fields containing decimal degrees to 4 decimal places spatial information. Records with no latitude/longitude information were removed from the data set. Next the newly created PLNT16.SHP projection was defined as GCS_WGS_1984, and then it was reprojected to the FGDL Albers NAD 83 HARN projection. Next a selection was performed on the State FIPS ID field where it was equal to 12 (i.e. the State of Florida). Several other power plants that skirted the Florida border were also included. Next the selection was exported to a new shapefile called EPAEGRID_2019.SHP Next all of the field information was Upper Cased, and five fields were added; NOTES, NUCLEAR, DESCRIPT (based on PNAME), FGDLAQDATE (based on the date the data was downloaded from the Source). Facilities no longer in operation were designated as (CLOSED) in the DESCRIPT field. Planned facilities were designated as (PROPOSED) in the DESCRIPT field. Information on closed and proposed facilities was obtained via google and from the following website: http://www.energyjustice.net/map/searchfacility-basic.php. Certain points were moved, see NOTES field for features altered. Facility address information from the following website was used to help better locate the physical locations of the facilities: http://www.energyjustice.net/map/searchfacility-basic.php Two new fields were added to the table since the previous update: PLC2ECRT and CHPN2O. The following fields were added by GeoPlan: LAT_DD, LONG_DD, MGRS, GOOGLEMAP, DESCRIPT, and FGDLAQDATE. See field definitions for more info.</procdesc>
        <srcused>GeoPlan</srcused>
        <procdate>20210706</procdate>
      </procstep>
    </lineage>
  </dataqual>
  <spdoinfo>
    <direct>Vector</direct>
    <ptvctinf>
      <sdtsterm>
        <sdtstype>Entity point</sdtstype>
        <ptvctcnt>285</ptvctcnt>
      </sdtsterm>
    </ptvctinf>
  </spdoinfo>
  <spref>
    <horizsys>
      <planar>
        <mapproj>
          <mapprojn>NAD 1983 HARN Florida GDL Albers</mapprojn>
          <albers>
            <stdparll>24.0</stdparll>
            <stdparll>31.5</stdparll>
            <longcm>-84.0</longcm>
            <latprjo>24.0</latprjo>
            <feast>400000.0</feast>
            <fnorth>0.0</fnorth>
          </albers>
        </mapproj>
        <planci>
          <plance>coordinate pair</plance>
          <coordrep>
            <absres>0.0001</absres>
            <ordres>0.0001</ordres>
          </coordrep>
          <plandu>meter</plandu>
        </planci>
      </planar>
      <geodetic>
        <horizdn>D North American 1983 HARN</horizdn>
        <ellips>GRS 1980</ellips>
        <semiaxis>6378137.0</semiaxis>
        <denflat>298.257222101</denflat>
      </geodetic>
    </horizsys>
  </spref>
  <eainfo>
    <detailed>
      <enttyp>
        <enttypl>EPAEGRID_2019</enttypl>
        <enttypd>EPAEGRID_2019.DBF</enttypd>
        <enttypds>U.S. Environmental Protection Agency</enttypds>
      </enttyp>
      <attr>
        <attrlabl>Shape</attrlabl>
        <attrdef>Feature geometry.</attrdef>
        <attrdefs>ESRI</attrdefs>
        <attrdomv>
          <udom>Coordinates defining the features.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>SEQPLT19</attrlabl>
        <attrdef>eGRID2019 File Plant Sequence Number (SEQPLT19) - The plant records in the 2019 plant data file are sorted by state abbreviation and plant name, and are assigned a unique sequential number beginning with 1. This sequence number is unlikely to be the same as the sequence number in the eGRID2018 file for the same entity.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>YEAR</attrlabl>
        <attrdef>Data Year (YEAR) - The current eGRID data year.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PSTATABB</attrlabl>
        <attrdef>Plant State Abbreviation (PSTATABB) - The state abbreviation in which the plant is located..</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>PNAME</attrlabl>
        <attrdef>Plant Name (PNAME) - The name associated with each plant.</attrdef>
        <attrdefs>EPA/CAMD; EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>ORISPL</attrlabl>
        <attrdef>DOE/EIA ORIS Plant or Facility Code (ORISPL) - This plant code corresponds to PNAME and was originally developed for power plants by the Office of Regulatory Information Systems (ORIS), which was a part of the Federal Power Commission. It is now assigned by EIA and is used as a unique plant identification code for many EPA electric power databases, too. Note that some EIA ORISPL ID codes were changed to reflect EPA/CAMD ORISPL ID codes. See Section 4.1 for a discussion of ORISPL ID changes made to eGRID2016. See Table C-5 in Appendix C for a table of all ORISPL changes made between EIA and EPA/CAMD.</attrdef>
        <attrdefs>EPA/CAMD; EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>OPRNAME</attrlabl>
        <attrdef>Plant Operator Name (OPRNAME) - The name associated with each operating company (EGC).</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>OPRCODE</attrlabl>
        <attrdef>Plant Operator ID (OPRCODE) - The operating company ID. Each operating company has a unique company code assigned by EIA, with some exceptions. Plants with no operating company ID.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>UTLSRVNM</attrlabl>
        <attrdef>Utility Service Territory Name (UTLSRVNM) - The name of the owner of the transmission/distribution company/EGC, also known as the utility service territory (a utility company or EGC) [and previously known as the utility service area] in which the plant is located.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>UTLSRVID</attrlabl>
        <attrdef>Utility Service Territory ID (UTLSRVID) - The unique ID code associated with the utility service territory name.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>SECTOR</attrlabl>
        <attrdef>Plant-level Sector (SECTOR) - The plant level sector name, assigned by the purpose, regulatory status, and CHP status at the plant.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>BANAME</attrlabl>
        <attrdef>Balancing Authority Name (BANAME) - The name of the balancing authority for the plant. The balancing authority is associated with the plant's eGRID subregion and NERC region.</attrdef>
        <attrdefs>EIA-860, EIA-861</attrdefs>
      </attr>
      <attr>
        <attrlabl>OBJECTID</attrlabl>
        <attrdef>Internal feature number.</attrdef>
        <attrdefs>Esri</attrdefs>
        <attrdomv>
          <udom>Sequential unique whole numbers that are automatically generated.</udom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>BACODE</attrlabl>
        <attrdef>Balancing Authority ID Code (BACODE) - The ID of the balancing authority for the plant.</attrdef>
        <attrdefs>EIA-860, EIA-861</attrdefs>
      </attr>
      <attr>
        <attrlabl>NERC</attrlabl>
        <attrdef>NERC Region Acronym (NERC) - The acronym for the NERC region in which the plant is located. The NERC region is associated with the plant's BA and eGRID subregion. A representation of the eGRID NERC region map is included in Appendix B.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>SUBRGN</attrlabl>
        <attrdef>eGRID Subregion Acronym (SUBRGN) - The acronym for the eGRID subregion in which the plant is located. The eGRID subregion is associated with the plant's balancing authority and NERC region. A representation of the eGRID subregion map is included in Appendix B.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>SRNAME</attrlabl>
        <attrdef>eGRID Subregion Name (SRNAME) - The name of the eGRID subregion in which the plant is located.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>ISORTO</attrlabl>
        <attrdef>Plant associated ISO/RTO Territory (ISORTO) - The name, if applicable, of the Independent System Operator (ISO) or Regional Transmission Organization (RTO) associated with the plant. Possible values are CAISO, ERCOT, ISONE, MISO, NYISO, PJM, SPP, OTHER, or blank.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>FIPSST</attrlabl>
        <attrdef>Plant FIPS State Code (FIPSST) - The two-digit Federal Information Processing Standards (FIPS) state character code of the state in which the plant is located. The codes are from the National Institute of Standards and Technology (US Census, 2016).</attrdef>
        <attrdefs>US Census</attrdefs>
      </attr>
      <attr>
        <attrlabl>FIPSCNTY</attrlabl>
        <attrdef>Plant FIPS County Code (FIPSCNTY) - The three digit FIPS county character code of the county in which the plant is located. The codes are from the National Institute of Standards and Technology (US Census, 2016).</attrdef>
        <attrdefs>US Census</attrdefs>
      </attr>
      <attr>
        <attrlabl>CNTYNAME</attrlabl>
        <attrdef>Plant County Name (CNTYNAME) - The name of the county in which the plant is located.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>LAT</attrlabl>
        <attrdef>Plant Latitude (LAT) - The latitude, in degrees to four decimal places, associated with the plant.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>LON</attrlabl>
        <attrdef>Plant Longitude (LON) - The longitude, in degrees to four decimal places, associated with the plant.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>NUMUNT</attrlabl>
        <attrdef>Number of Units (NUMUNT) - The number of operating units within a plant.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>NUMGEN</attrlabl>
        <attrdef>Number of Generators (NUMGEN) - The number of potentially operating generators within a plant.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLPRMFL</attrlabl>
        <attrdef>Plant Primary Fuel (PLPRMFL) - The plant's primary fuel based on maximum heat input of fuel consumed by the plant. If the plant does not consume fuel, it is based on the maximum nameplate capacity.</attrdef>
        <attrdefs>EPA/CAMD; EIA-860</attrdefs>
        <attrdomv>
          <edom>
            <edomv>AB</edomv>
            <edomvd>Agricultural byproduct</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>BFG</edomv>
            <edomvd>Blast furnace gas</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>BIT</edomv>
            <edomvd>Bituminous coal</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>BLQ</edomv>
            <edomvd>Black liquor</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>COG</edomv>
            <edomvd>Coke oven gas</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>DFO</edomv>
            <edomvd>Distillate fuel oil, light fuel oil, diesel oil</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>GEO</edomv>
            <edomvd>Geothermal steam</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>JF</edomv>
            <edomvd>Jet fuel</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>KER</edomv>
            <edomvd>Kerosene</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>LFG</edomv>
            <edomvd>Landfill gas</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>LIG</edomv>
            <edomvd>Lignite coal</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>MSW</edomv>
            <edomvd>Municipal solid waste</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>MWH</edomv>
            <edomvd>Electricity used for energy storage (megawatt hour)</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>OBG</edomv>
            <edomvd>Other biomass gas</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>OBL</edomv>
            <edomvd>Other biomass liquid</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>OBS</edomv>
            <edomvd>Other biomass solid</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>OG</edomv>
            <edomvd>Other gas</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>OTH</edomv>
            <edomvd>Other (unknown)</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>PC</edomv>
            <edomvd>Petroleum coke</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>PRG</edomv>
            <edomvd>Process gas</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>PUR</edomv>
            <edomvd>Purchased fuel (unknown)</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>RC</edomv>
            <edomvd>Refined coal</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>RFO</edomv>
            <edomvd>Residual fuel oil, heavy fuel oil, petroleum</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>SGC</edomv>
            <edomvd>Coal-derived synthetic gas</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>SUB</edomv>
            <edomvd>Subbituminous coal</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>SUN</edomv>
            <edomvd>Sun</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>TDF</edomv>
            <edomvd>Tire-derived fuel</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>WC</edomv>
            <edomvd>Waste coal</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>WDL</edomv>
            <edomvd>Wood, wood waste liquid</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>WDS</edomv>
            <edomvd>Wood, wood waste solid</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>WH</edomv>
            <edomvd>Waste heat</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>WND</edomv>
            <edomvd>Wind</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>WO</edomv>
            <edomvd>Waste oil</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>NG</edomv>
            <edomvd>Natural gas</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>NUC</edomv>
            <edomvd>Nuclear material</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
          <edom>
            <edomv>WAT</edomv>
            <edomvd>Water</edomvd>
            <edomvds>EPA</edomvds>
          </edom>
        </attrdomv>
      </attr>
      <attr>
        <attrlabl>PLFUELCT</attrlabl>
        <attrdef>Plant Primary Fuel Category (PLFUELCT) - The fuel category for the primary fuel of the plant.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>COALFLAG</attrlabl>
        <attrdef>Flag indicating if the plant burned or generated any amount of coal (COALFLAG) - A flag to indicate if the plant burned or, if it has positive heat input and generated electricity from coal (1= Yes). The plant will not be flagged if the plant has negative coal generation and no coal heat input for a given year.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CAPFAC</attrlabl>
        <attrdef>Plant Capacity Factor (CAPFAC) - The plant capacity factor, expressed with four decimal places. It is calculated as follows: CAPFAC = (PLNGENAN / (NAMEPCAP * 8760)) Although the value should be between 0 and 1, there are outliers.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>NAMEPCAP</attrlabl>
        <attrdef>Plant Nameplate Capacity (NAMEPCAP) - The nameplate capacity of the plant, in MW.</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>NBFACTOR</attrlabl>
        <attrdef>Nonbaseload Factor (NBFACTOR) - The proportion of generation that is considered nonbaseload generation. A value of 0 means none of the generation is nonbaseload generation. See Section 3 for more information.</attrdef>
        <attrdefs>Calculated</attrdefs>
      </attr>
      <attr>
        <attrlabl>RMBMFLAG</attrlabl>
        <attrdef>Biogas/Biomass Plant Adjustment Flag (RMBMFLAG) - A biogas (landfill gas, digester gas)/biomass adjustment flag, used to indicate where emissions were adjusted for plants using biogas or biomass fuels (1=Yes). A facility's emissions reported in eGRID may be different</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPFLAG</attrlabl>
        <attrdef>Combined Heat and Power (CHP) Plant Adjustment Flag (CHPFLAG) - A flag to indicate if the plant is a CHP facility (1=Yes). A CHP facility's emissions and heat input reported in eGRID may be different from that reported in other EPA sources such as EPA/CAMD's emissions data, due to this adjustment.</attrdef>
        <attrdefs>EPA/CAMD; EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>USETHRMO</attrlabl>
        <attrdef>CHP Plant Useful Thermal Output (USETHRMO) - The useful thermal output, in MMBtu, estimated for a CHP facility.</attrdef>
        <attrdefs>EIA-923 calculated</attrdefs>
      </attr>
      <attr>
        <attrlabl>PWRTOHT</attrlabl>
        <attrdef>CHP Plant Power to Heat Ratio (PWRTOHT) - The power to heat ratio for a CHP facility, which is the ratio of the heat value of electricity generated (3413 * kWh output) to the facility's useful thermal output.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>ELCALLOC</attrlabl>
        <attrdef>CHP Plant Electric Allocation Factor (ELCALLOC) - The CHP plant's decimal fraction of the emissions that are attributed to electricity. It is derived as the ratio of the electric heat output to the sum of the electric and steam heat outputs, where the steam output is 75% of the useful thermal output. The electric allocation factor is used to allocate emissions from a CHP facility to both electricity generation and useful thermal output. For non-CHP plants, eGRID uses an electric allocation factor of 1.0.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PSFLAG</attrlabl>
        <attrdef>Plant Pumped Storage Flag (PSFLAG) - Indicates if the plant has at least one pumped storage generator (1= Yes).</attrdef>
        <attrdefs>EIA-860</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHTIAN</attrlabl>
        <attrdef>Plant Annual Heat Input from Combustion (PLHTIAN) - The total annual heat input from combustion, in MMBtu, for the plant. For CHP plants, the value is adjusted by the electric allocation factor.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHTIOZ</attrlabl>
        <attrdef>Plant Ozone Season Heat Input from Combustion (PLHTIOZ) - The five-month ozone season (May through September) heat input from combustion, in MWh, for the plant. For CHP plants, the value is adjusted by the electric allocation factor.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHTIANT</attrlabl>
        <attrdef>Plant Total Annual Heat Input (PLHTIANT) - The total annual heat input from combustion and noncombustion units, in MMBtu, for the plant. For CHP plants, the value is adjusted by the electric allocation factor.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHTIOZT</attrlabl>
        <attrdef>Plant Total Ozone Season Heat Input (PLHTIOZT) - The five-month ozone season (May through September) heat input from combustion and noncombustion units, in MWh, for the plant. For CHP plants, the value is adjusted by the electric allocation factor.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNGENAN</attrlabl>
        <attrdef>Plant Annual Net Generation (PLNGENAN) - The total reported annual net generation, in MWh, for the plant, summed from the Unit file</attrdef>
        <attrdefs>EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNGENOZ</attrlabl>
        <attrdef>Plant Ozone Season Net Generation (PLNGENOZ) - The five-month ozone season (May through September) net generation for the plant.</attrdef>
        <attrdefs>EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNOXAN</attrlabl>
        <attrdef>Plant Annual NOx Emissions (PLNOXAN) - The total annual NOx emissions, in short tons, for the plant. Biogas components are adjusted. For CHP plants, the value is adjusted by the electric allocation factor. This adjusted emissions field is estimated by first making the biogas adjustment (if it exists) and then applying the electric allocation factor (if the plant is a CHP).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNOXOZ</attrlabl>
        <attrdef>Plant Ozone Season NOx Emissions (PLNOXOZ) - The five-month ozone season (May through September) NOx emissions, in short tons, for the plant. Biogas components are adjusted. For CHP plants, the value is adjusted by the electric allocation factor. This adjusted emissions field is estimated by first making the biogas adjustment (if it exists) and then applying the electric allocation factor (if the plant is a CHP).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLSO2AN</attrlabl>
        <attrdef>Plant Annual SO2 Emissions (PLSO2AN) - The total annual SO2 emissions, in short tons, for the plant. Landfill gas components are adjusted. For CHP plants, the value is adjusted by the electric allocation factor. This adjusted emissions field is estimated by first making the landfill gas adjustment (if it exists) and then applying the electric allocation factor (if the plant is a CHP).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCO2AN</attrlabl>
        <attrdef>Plant Annual CO2 Emissions (PLCO2AN) - The total annual CO2 emissions, in short tons, for the plant. All CO2 emissions from biomass fuels are adjusted to zero. For CHP plants, the value is adjusted by the electric allocation factor. This adjusted emissions field is estimated by first making the biomass adjustment (if it exists) and then applying the electric allocation factor (if the plant is a CHP).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCH4AN</attrlabl>
        <attrdef>Plant Annual CH4 Emissions (PLCH4AN) - The total annual CH4 emissions, in pounds, for the plant. Biogas biomass components are adjusted. For CHP plants, the value is adjusted by the electric allocation factor. This adjusted emissions field is estimated by first making the biomass adjustment (if it exists) and then applying the electric allocation factor (if the plant is a CHP).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLN2OAN</attrlabl>
        <attrdef>Plant Annual N2O Emissions (PLN2OAN) - The total annual N2O emissions, in pounds for the plant. Biogas biomass components are adjusted. For CHP plants, the value is adjusted by the electric allocation factor. This adjusted emissions field is estimated by first making the biomass adjustment (if it exists) and then applying the electric allocation factor (if the plant is a CHP).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCO2EQA</attrlabl>
        <attrdef>Plant Annual CO2 Equivalent Emissions (PLCO2EQA) - The annual CO2 equivalent emissions, in short tons, for the plant. This value is a universal standard of measurement. The GWPs from the second IPCC assessment are used per EPA for the calculation; the formula used is as follows: PLCO2EQA = ((1* PLCO2AN) + (21* PLCH4AN / 2000) + (310 * PLN2OAN / 2000)).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHGAN</attrlabl>
        <attrdef>Plant Annual Hg Emissions (PLHGAN) - The total annual Hg emissions, in pounds for the plant. For CHP plants, the value is adjusted by the electric allocation factor. Not calculated for eGRID2016.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNOXRTA</attrlabl>
        <attrdef>Plant Annual NOx Total Output Emission Rate (PLNOXRTA) - This field, in lb/MWh, is calculated as follows: PLNOXRTA = 2000 * (PLNOXAN / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNOXRTO</attrlabl>
        <attrdef>Plant Ozone Season NOx Total Output Emission Rate (PLNOXRTO) - This field, in lb/MWh, is calculated as follows: PLNOXRTO = 2000 * (PLNOXOZ / PLNGENOZ).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLSO2RTA</attrlabl>
        <attrdef>Plant Annual SO2 Total Output Emission Rate (PLSO2RTA) - This field, in lb/MWh, is calculated as follows: PLSO2RTA = 2000 * (PLSO2AN / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCO2RTA</attrlabl>
        <attrdef>Plant Annual CO2 Total Output Emission Rate (PLCO2RTA) - This field, in lb/MWh, is calculated as follows: PLCO2RTA = 2000 * (PLCO2AN / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCH4RTA</attrlabl>
        <attrdef>Plant Annual CH4 Total Output Emission Rate (PLCH4RTA) - This field, in lb/GWh, is calculated as follows: PLCH4RTA = PLCH4AN / (PLNGENAN / 1000).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLN2ORTA</attrlabl>
        <attrdef>Plant Annual N2O Total Output Emission Rate (PLN2ORTA) - This field, in lb/GWh, is calculated as follows: PLN2ORTA = PLN2OAN / (PLNGENAN / 1000).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLC2ERTA</attrlabl>
        <attrdef>Plant Annual CO2 Equivalent Total Output Emission Rate (PLC2ERTA) - This field, in lb/MWh, is calculated as follows: PLC2ERTA = 2000 * (PLCO2EQA / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHGRTA</attrlabl>
        <attrdef>Plant Annual Hg Total Output Emission Rate (PLHGRTA) - This field, in lb/GWh, is calculated as follows: PLHGRTA = PLHGAN / (PLNGENAN / 1000). Not calculated for eGRID2016.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNOXRA</attrlabl>
        <attrdef>Plant Annual NOx Input Emission Rate (PLNOXRA) - This field, in lb/MMBtu, is calculated as follows: PLNOXRA = 2000 * (PLNOXAN / PLHTIAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNOXRO</attrlabl>
        <attrdef>Plant Ozone Season NOx Input Emission Rate (PLNOXRO) - This field, in lb/MMBtu, is calculated as follows: PLNOXRO = 2000 * (PLNOXOZ / PLHTIOZ).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLSO2RA</attrlabl>
        <attrdef>Plant Annual SO2 Input Emission Rate (PLSO2RA) - This field, in lb/MMBtu, is calculated as follows: PLSO2RA = 2000 * (PLSO2AN / PLHTIAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCO2RA</attrlabl>
        <attrdef>Plant Annual CO2 Input Emission Rate (PLCO2RA) - This field, in lb/MMBtu, is calculated as follows: PLCO2RA = 2000 * (PLCO2AN / PLHTIAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCH4RA</attrlabl>
        <attrdef>Plant Annual CH4 Input Emission Rate (PLCH4RA) - This field, in lb/MMBtu, is calculated as follows: PLCO2RA = 2000 * (PLCH4AN / PLHTIAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLN2ORA</attrlabl>
        <attrdef>Plant Annual N2O Input Emission Rate (PLN2ORA) - This field, in lb/MMBtu, is calculated as follows: PLCO2RA = 2000 * (PLN2OAN / PLHTIAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLC2ERA</attrlabl>
        <attrdef>Plant Annual CO2 Equivalent Input Emission Rate (PLC2ERA) - This field, in lb/MMBtu, is calculated as follows: PLCO2RA = 2000 * (PLCO2EQA / PLHTIAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHGRA</attrlabl>
        <attrdef>Plant Annual Hg Input Emission Rate (PLHGRA) - This field, in lb/BBtu, is calculated as follows: PLHGRA = PLHGAN / (PLHTIAN / 1000). Not calculated for eGRID2016.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNOXCRT</attrlabl>
        <attrdef>Plant Annual NOx Combustion Output Emission Rate (PLNOXCRT) - This field, in lb/MWh, is calculated as follows: PLNOXCRT = 2000 * (PLNOXAN / PLGENACY).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNOXCRO</attrlabl>
        <attrdef>Plant Ozone Season NOx Combustion Output Emission Rate (PLNOXCRO) - This field, in lb/MWh, is calculated as follows: PLNOXCRO = 2000 * (PLNOXOZ / ((PLGENACY * PLNGENOZ) / PLNGENAN)).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLSO2CRT</attrlabl>
        <attrdef>Plant Annual SO2 Combustion Output Emission Rate (PLSO2CRT) - This field, in lb/MWh, is calculated as follows: PLSO2CRT = 2000 * (PLSO2AN / PLGENACY).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCO2CRT</attrlabl>
        <attrdef>Plant Annual CO2 Combustion Output Emission Rate (PLCO2CRT) - This field, in lb/MWh, is calculated as follows: PLCO2CRT = 2000 * (PLCO2AN / PLGENACY).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCH4CRT</attrlabl>
        <attrdef>Plant Annual CH4 Combustion Output Emission Rate (PLCH4CRT) - This field, in lb/GWh, is calculated as follows: PLCH4CRT = PLCH4AN / (PLGENACY / 1000).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLN2OCRT</attrlabl>
        <attrdef>Plant Annual N2O Combustion Output Emission Rate (PLN2OCRT) - This field, in lb/GWh, is calculated as follows: PLN2OCRT = PLN2OAN / (PLGENACY / 1000).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLC2ECRT</attrlabl>
        <attrdef>Plant Annual CO2 Equivalent Combustion Output Emission Rate (PLC2ECRT) - This field, in lb/MWh, is calculated as follows: PLC2ECRT = 2000 * (PLCO2EQA / PLGENACY). </attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHGCRT</attrlabl>
        <attrdef>Plant Annual Hg Combustion Output Emission Rate (PLHGCRT) - This field, in lb/GWh, is calculated as follows: PLHGCRT = PLHGAN / (PLGENACY / 1000). Not calculated for eGRID2019.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNNOX</attrlabl>
        <attrdef>Plant Unadjusted Annual NOx Emissions (UNNOX) - The total plant-level unadjusted annual NOx emissions, in short tons.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNNOXOZ</attrlabl>
        <attrdef>Plant Unadjusted Ozone Season NOx Emissions (UNNOXOZ) - The unadjusted five-month ozone season (May through September) NOx emissions, in short tons, for the plant.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNSO2</attrlabl>
        <attrdef>Plant Unadjusted Annual SO2 Emissions (UNSO2) - The total plant-level unadjusted annual SO2 emissions, in short tons.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNCO2</attrlabl>
        <attrdef>Plant Unadjusted Annual CO2 Emissions (UNCO2) - The total plant-level unadjusted annual CO2 emissions, in short tons.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNCH4</attrlabl>
        <attrdef>Plant Unadjusted Annual CH4 Emissions (UNCH4) - The total plant-level unadjusted annual CH4 emissions, in pounds.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNN2O</attrlabl>
        <attrdef>Plant Unadjusted Annual N2O Emissions (UNN2O) - The total plant-level unadjusted annual N2O emissions, in pounds.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNHG</attrlabl>
        <attrdef>Plant Unadjusted Annual Hg Emissions (UNHG) - The total plant-level unadjusted annual Hg emissions, in pounds. Not calculated for eGRID2016.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNHTI</attrlabl>
        <attrdef>Plant Unadjusted Annual Heat Input from Combustion (UNHTI) - The total plant-level unadjusted annual heat input from combustion, in MMBtu.</attrdef>
        <attrdefs>EPA/CAMD, EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNHTIOZ</attrlabl>
        <attrdef>Plant Unadjusted Ozone Season Heat Input from Combustion (UNHTIOZ) - The five-month ozone season (May through September) heat input from combustion, in MMBtu for the plant</attrdef>
        <attrdefs>EPA/CAMD, EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNHTIT</attrlabl>
        <attrdef>Plant Total Unadjusted Annual Heat Input (UNHTIT) - The total plant-level unadjusted annual heat input from combustion and noncombustion units, in MMBtu.</attrdef>
        <attrdefs>EPA/CAMD, EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNHTIOZT</attrlabl>
        <attrdef>Plant Total Unadjusted Ozone Season Heat Input (UNHTIOZT) - The five-month ozone season (May through September) heat input from combustion and noncombustion units, in MMBtu for the plant.</attrdef>
        <attrdefs>EPA/CAMD, EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNNOXSRC</attrlabl>
        <attrdef>Plant Unadjusted Annual NOx Emissions Source (UNNOXSRC ) - The source of plant-level unadjusted annual NOx emissions.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNNOZSRC</attrlabl>
        <attrdef>Plant Unadjusted Ozone Season NOx Emissions Source (UNNOZSRC) - The source of plant-level unadjusted ozone NOx emissions.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNSO2SRC</attrlabl>
        <attrdef>Plant Unadjusted Annual SO2 Emissions Source (UNSO2SRC) - The source of plant-level unadjusted annual SO2 emissions.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNCO2SRC</attrlabl>
        <attrdef>Plant Unadjusted Annual CO2 Emissions Source (UNCO2SRC) - The source of plant-level unadjusted annual CO2 emissions.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNCH4SRC</attrlabl>
        <attrdef>Plant Unadjusted Annual CH4 Emissions Source (UNCH4SRC) - The source of plant-level unadjusted annual CH4 emissions.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNN2OSRC</attrlabl>
        <attrdef>Plant Unadjusted Annual N2O Emissions Source (UNN2OSRC) - The source of plant-level unadjusted annual N2O emissions.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNHGSRC</attrlabl>
        <attrdef>Plant Unadjusted Annual Hg Emissions Source (UNHGSRC) - The source of plant-level unadjusted annual Hg emissions. Not calculated for eGRID2016.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNHTISRC</attrlabl>
        <attrdef>Plant Unadjusted Annual Heat Input Source (UNHTISRC) - The source of plant-level unadjusted annual heat input.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>UNHOZSRC</attrlabl>
        <attrdef>Plant Unadjusted Ozone Season Heat Input Source (UNHOZSRC) - The source of plant-level unadjusted ozone season heat input.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>BIONOX</attrlabl>
        <attrdef>Plant Annual NOx Biomass Emissions (BIONOX) - The annual plant-level NOx biomass emissions, in tons. This is the value the total emissions are adjusted by for the biomass emissions adjustments.</attrdef>
        <attrdefs>EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>BIONOXOZ</attrlabl>
        <attrdef>Plant Ozone Season NOx Biomass Emissions (BIONOXOZ) - The five-month ozone season (May through September) plant-level NOx biomass emissions, in tons. This is the value the total emissions are adjusted by for the biomass emissions adjustments.</attrdef>
        <attrdefs>EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>BIOSO2</attrlabl>
        <attrdef>Plant Annual SO2 Biomass Emissions (BIOSO2) - The annual plant-level SO2 biomass emissions, in tons. This is the value the total emissions are adjusted by for the biomass emissions adjustments.</attrdef>
        <attrdefs>EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>BIOCO2</attrlabl>
        <attrdef>Plant Annual CO2 Biomass Emissions (BIOCO2) - The annual plant-level CO2 biomass emissions, in tons. This is the value the total emissions are adjusted by for the biomass emissions adjustments.</attrdef>
        <attrdefs>EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>BIOCH4</attrlabl>
        <attrdef>Plant Annual CH4 Biomass Emissions (BIOCH4) - The annual plant-level CH4 biomass emissions, in pounds. This is the value the total emissions are adjusted by for the biomass emissions adjustments.</attrdef>
        <attrdefs>EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>BION2O</attrlabl>
        <attrdef>Plant Annual N2O Biomass Emissions (BION2O) - The annual plant-level N2O biomass emissions, in pounds. This is the value the total emissions are adjusted by for the biomass emissions adjustments.</attrdef>
        <attrdefs>EIA-923</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPCHTI</attrlabl>
        <attrdef>Plant Combustion Annual Heat Input CHP Adjustment Value (CHPCHTI) &#8211; The annual plant-level heat input adjustment value for CHP plants, in MMBtu</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPCHTIOZ</attrlabl>
        <attrdef>Plant Combustion Ozone Season Heat Input CHP Adjustment Value (CHPCHTIOZ) - The five-month ozone season (May through September) plant-level heat input adjustment value for CHP plants, in MMBtu.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPNOX</attrlabl>
        <attrdef>Plant Annual NOx Emissions CHP Adjustment Value (CHPNOX) - The annual plant-level NOx emissions adjustment value for CHP plants, in tons.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPNOXOZ</attrlabl>
        <attrdef>Plant Ozone season NOx Emissions CHP Adjustment Value (CHPNOXOZ) - The five-month ozone season (May through September) plant-level NOx emissions adjustment value for CHP plants, in tons.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPSO2</attrlabl>
        <attrdef>Plant Annual SO2 Emissions CHP Adjustment Value (CHPSO2) - The annual plant-level SO2 emissions adjustment value for CHP plants, in tons.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPCO2</attrlabl>
        <attrdef>Plant Annual CO2 Emissions CHP Adjustment Value (CHPCO2) - The annual plant-level CO2 emissions adjustment value for CHP plants, in tons.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPCH4</attrlabl>
        <attrdef>Plant Annual CH4 Emissions CHP Adjustment Value (CHPCH4) - The annual plant-level CH4 emissions adjustment value for CHP plants, in pounds.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>CHPN2O</attrlabl>
        <attrdef>Plant Annual N2O Emissions CHP Adjustment Value (CHPN2O) - The annual plant-level N2O emissionsadjustment value for CHP plants, in pounds.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHTRT</attrlabl>
        <attrdef>Plant Nominal Heat Rate (PLHTRT) - The plant nominal heat rate, in Btu/kWh, for at least partially combusted plants. It is calculated as follows: PLHTRT = 1000 * (PLHTIAN / PLNGENAN) for combustion plants; and PLHTRT = 1000 * (PLHTIAN / PLGENACY) for partial combustion plants. For CHP plants, the value is, in effect, adjusted by the electric allocation factor, since the heat input has been adjusted.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENACL</attrlabl>
        <attrdef>Plant Annual Coal Net Generation (PLGENACL) - The plant annual net generation, in MWh, for coal. Fuel codes that are included in coal are BIT, COG, SUB, LIG, WC, and SC.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENAOL</attrlabl>
        <attrdef>Plant Annual Oil Net Generation (PLGENAOL) - The plant annual net generation, in MWh, for oil. Fuel codes included in oil are DFO, JF, KER, OO, PC, RFO, RG, and WO.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENAGS</attrlabl>
        <attrdef>Plant Annual Gas Net Generation (PLGENAGS) - The plant annual net generation, in MWh, for natural gas. Fuel codes included in gas are NG and PG.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENANC</attrlabl>
        <attrdef>Plant Annual Nuclear Net Generation (PLGENANC) - The plant annual net generation, in MWh, for nuclear. Fuel codes include NUC.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENAHY</attrlabl>
        <attrdef>Plant Annual Hydro Net Generation (PLGENAHY) - The plant annual net generation, in MWh, for hydro. Fuel codes include WAT.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENABM</attrlabl>
        <attrdef>Plant Annual Biomass Net Generation (PLGENABM) - The annual net generation, in MWh, for biomass. Biomass is a fuel derived from organic matter such as wood and paper products, agricultural waste, or methane (e.g., from landfills). The renewable portion of solid waste, fuel code MSB, is included as biomass, as are AB, BLQ, DG, LFG, ME, OBL, OBS, PP, SLW, WDL, and WDS.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENAWI</attrlabl>
        <attrdef>Plant Annual Wind Net Generation (PLGENAWI) - The plant annual net generation, in MWh, for wind. Fuel codes include WND.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENASO</attrlabl>
        <attrdef>Plant Annual Solar Net Generation (PLGENASO) - The plant annual net generation, in MWh, for solar. Fuel codes include SUN.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENAGT</attrlabl>
        <attrdef>Plant Annual Geothermal Net Generation (PLGENAGT) - The plant annual net generation, in MWh, for geothermal. Fuel codes include GEO.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENAOF</attrlabl>
        <attrdef>Plant Annual Other Fossil Net Generation (PLGENAOF) - The plant annual net generation, in MWh, for other fossil fuel that cannot be categorized as coal, oil, or gas. Other fossil fuel codes include BFG, COG, HY, LB, MH, MSF, OG, PRG, and TDF.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENAOP</attrlabl>
        <attrdef>Plant Annual Other Unknown/ Purchased Fuel Net Generation (PLGENAOP) - The plant annual net generation, in MWh, for other unknown/purchased. Fuel codes include OTH, PUR, or WH.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENATN</attrlabl>
        <attrdef>Plant Annual Total Nonrenewables Net Generation (PLGENATN) - The annual total nonrenewables net generation, in MWh, for the plant. Nonrenewables are exhaustible energy resources such as coal, oil, gas, other fossil, nuclear power, and other unknown/purchased fuel. This field is the sum of PLGENACL, PLGENAOL, PLGENAGS, PLGENAOF, PLGENANC, and PLGENAOP.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENATR</attrlabl>
        <attrdef>Plant Annual Total Renewables Net Generation (PLGENATR) - The annual total renewables net generation, in MWh, for the plant. Renewables are inexhaustible energy resources such as biomass, wind, solar, geothermal, and hydro. This field is the sum of PLGENABM, PLGENAWI, PLGENASO, PLGENAGT, and PLGENAHY.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENATH</attrlabl>
        <attrdef>Plant Annual Total Nonhydro Renewables Net Generation (PLGENATH) - The annual total nonhydro renewables net generation, in MWh, for the plant. This field is the sum of PLGENABM, PLGENAWI, PLGENASO, and PLGENAGT.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENACY</attrlabl>
        <attrdef>Plant Annual Total Combustion Net Generation (PLGENACY) - The annual total combustion net generation, in MWh, for the plant. This field is the sum of PLGENACL, PLGENAOL, PLGENAGS, PLGENAOF, PLGENABM, and PLGENAOP.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGENACN</attrlabl>
        <attrdef>Plant Annual Total Noncombustion Net Generation (PLGENACN) - The annual total noncombustion net generation, in MWh, for the plant. This field is the sum of PLGENANC, PLGENAHY, PLGENAWI, PLGENASO, and PLGENAGT.</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCLPR</attrlabl>
        <attrdef>Plant Coal Generation Percent (PLCLPR) - The coal resource mix expressed as a percent of plant annual net generation. PLCLPR = 100 * (PLGENACL / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLOLPR</attrlabl>
        <attrdef>Plant Oil Generation Percent (PLOLPR) - The oil resource mix expressed as a percent of plant annual net generation. PLOLPR = 100 * (PLGENAOL / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGSPR</attrlabl>
        <attrdef>Plant Gas Generation Percent (PLGSPR) - The gas resource mix expressed as a percent of plant annual net generation. PLGSPR = 100 * (PLGENAGS / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLNCPR</attrlabl>
        <attrdef>Plant Nuclear Generation Percent (PLNCPR) - The nuclear resource mix expressed as a percent of plant annual net generation. PLNCPR = 100 * (PLGENANC / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLHYPR</attrlabl>
        <attrdef>Plant Hydro Generation Percent (PLHYPR) - The hydro resource mix expressed as a percent of plant annual net generation. PLHYPR = 100 * (PLGENAHY / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLBMPR</attrlabl>
        <attrdef>Plant Biomass Generation Percent (PLBMPR) - The biomass resource mix expressed as a percent of plant annual net generation. PLBMPR = 100 * (PLGENABM / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLWIPR</attrlabl>
        <attrdef>Plant Wind Generation Percent (PLWIPR) - The wind resource mix expressed as a percent of plant annual net generation. PLWIPR = 100 * (PLGENAWI / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLSOPR</attrlabl>
        <attrdef>Plant Solar Generation Percent (PLSOPR) - The solar resource mix expressed as a percent of plant annual net generation. PLSOPR = 100 * (PLGENASO / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLGTPR</attrlabl>
        <attrdef>Plant Geothermal Generation Percent (PLGTPR) - The geothermal resource mix expressed as a percent of plant annual net generation.: PLGTPR = 100 * (PLGENAGT / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLOFPR</attrlabl>
        <attrdef>Plant Other Fossil Generation Percent (PLOFPR) - The other fossil resource mix expressed as a percent of plant annual net generation. PLOFPR = 100 * (PLGENAOF / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLOPPR</attrlabl>
        <attrdef>Plant Other Unknown/Purchased Fuel Generation Percent (PLOPPR) - The other unknown/purchased fuel/waste heat resource mix expressed as a percent of plant annual net generation. PLOPPR = 100 * (PLGENAOP / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLTNPR</attrlabl>
        <attrdef>Plant Total Nonrenewables Generation Percent (PLTNPR) - The total nonrenewables resource mix expressed as a percent of plant annual net generation. PLTNPR = 100 * (PLGENATN / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLTRPR</attrlabl>
        <attrdef>Plant Total Renewables Generation Percent (PLTRPR) - The total renewables resource mix expressed as a percent of plant annual net generation. PLTRPR = 100 * (PLGENATR / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLTHPR</attrlabl>
        <attrdef>Plant Total Nonhydro Renewables Generation Percent (PLTHPR) - The total nonhydro renewables resource mix expressed as a percent of plant annual net generation. PLTHPR = 100 * (PLGENATH / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCYPR</attrlabl>
        <attrdef>Plant Total Combustion Generation Percent (PLCYPR) - The total combustion resource mix expressed as a percent of plant annual net generation. PLCYPR = 100 * (PLGENACY / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>PLCNPR</attrlabl>
        <attrdef>Plant Total Noncombustion Generation Percent (PLCNPR) - The total noncombustion resource mix expressed as a percent of plant annual net generation. PLCNPR = 100 * (PLGENACN / PLNGENAN).</attrdef>
        <attrdefs>EPA</attrdefs>
      </attr>
      <attr>
        <attrlabl>NOTES</attrlabl>
        <attrdef>Notes about the plant.</attrdef>
        <attrdefs>GeoPlan</attrdefs>
      </attr>
      <attr>
        <attrlabl>NUCLEAR</attrlabl>
        <attrdef>Whether the Plant uses nuclear power or not (YES = Nuclear Power Plant).</attrdef>
        <attrdefs>GeoPlan</attrdefs>
      </attr>
      <attr>
        <attrlabl>LAT_DD</attrlabl>
        <attrdef>Latitude in decimal degrees.</attrdef>
        <attrdefs>GeoPlan</attrdefs>
      </attr>
      <attr>
        <attrlabl>LONG_DD</attrlabl>
        <attrdef>Longitude in decimal degrees.</attrdef>
        <attrdefs>GeoPlan</attrdefs>
      </attr>
      <attr>
        <attrlabl>MGRS</attrlabl>
        <attrdef>Military Grid Reference System (MGRS) Coordinate of the Facility. The MGRS is the geocoordinate standard used by NATO militaries for locating points on the earth. The MGRS provides a means to represent any location on the surface of the Earth using an alphanumeric string. Hierarchical references are based on the Universal Transverse Mercator (UTM) coordinate system. The MGRS is used for the entire earth. http://mgrs-data.org/</attrdef>
        <attrdefs>GeoPlan</attrdefs>
      </attr>
      <attr>
        <attrlabl>GOOGLEMAP</attrlabl>
        <attrdef>Webpage hyperlink to location in Google Maps.</attrdef>
        <attrdefs>GeoPlan</attrdefs>
      </attr>
      <attr>
        <attrlabl>DESCRIPT</attrlabl>
        <attrdef>Based on PNAME.</attrdef>
        <attrdefs>GeoPlan</attrdefs>
      </attr>
      <attr>
        <attrlabl>FGDLAQDATE</attrlabl>
        <attrdef>The date FGDL acquired the data from the Source.</attrdef>
        <attrdefs>GeoPlan</attrdefs>
      </attr>
      <attr>
        <attrlabl>AUTOID</attrlabl>
      </attr>
    </detailed>
  </eainfo>
  <distinfo>
    <distrib>
      <cntinfo>
        <cntorgp>
          <cntorg>Florida Geographic Data Library (FGDL)</cntorg>
        </cntorgp>
        <cntaddr>
          <addrtype>mailing</addrtype>
          <address>431 Architecture PO Box 115706</address>
          <city>Gainesville</city>
          <state>Florida</state>
          <postal>32611-5706</postal>
          <country>US</country>
        </cntaddr>
        <cntemail>Mailing list for FGDL: http://www.fgdl.org/fgdl-l.html</cntemail>
      </cntinfo>
    </distrib>
    <resdesc>DOWNLOADABLE DATA</resdesc>
    <distliab>The Florida Geographic Data Library is a collection of Geospatial Data compiled by the University of Florida GeoPlan Center with support from the Florida Department of Transportation. GIS data available in FGDL is collected from various state, federal, and other agencies (data sources) who are data stewards, producers, or publishers. The data available in FGDL may not be the most current version of the data offered by the data source. University of Florida GeoPlan Center makes no guarantees about the currentness of the data and suggests that data users check with the data source to see if more recent versions of the data exist. Furthermore, the GIS data available in the FGDL are provided 'as is'. The University of Florida GeoPlan Center makes no warranties, guaranties or representations as to the truth, accuracy or completeness of the data provided by the data sources. The University of Florida GeoPlan Center makes no representations or warranties about the quality or suitability of the materials, either expressly or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. The University of Florida GeoPlan Center shall not be liable for any damages suffered as a result of using, modifying, contributing or distributing the materials. A note about data scale: Scale is an important factor in data usage. Certain scale datasets are not suitable for some project, analysis, or modeling purposes. Please be sure you are using the best available data. 1:24000 scale datasets are recommended for projects that are at the county level. 1:24000 data should NOT be used for high accuracy base mapping such as property parcel boundaries. 1:100000 scale datasets are recommended for projects that are at the multi-county or regional level. 1:125000 scale datasets are recommended for projects that are at the regional or state level or larger. Vector datasets with no defined scale or accuracy should be considered suspect. Make sure you are familiar with your data before using it for projects or analysis. Every effort has been made to supply the user with data documentation. For additional information, see the References section and the Data Source Contact section of this documentation. For more information regarding scale and accuracy, see our webpage at: http://geoplan.ufl.edu/education.html</distliab>
  </distinfo>
  <metainfo>
    <metd>20210727</metd>
    <metc>
      <cntinfo>
        <cntorgp>
          <cntorg>U.S. Environmental Protection Agency Clean Air Markets Division</cntorg>
        </cntorgp>
        <cntaddr>
          <addrtype>mailing</addrtype>
          <address>1200 Pennsylvania Avenue, NW (MC 6204M)</address>
          <city>Washington</city>
          <state>D.C.</state>
          <postal>20460</postal>
          <country>US</country>
        </cntaddr>
        <cntemail>https://www.epa.gov/egrid/forms/contact-us-about-egrid</cntemail>
      </cntinfo>
    </metc>
    <metstdn>FGDC Content Standard for Digital Geospatial Metadata</metstdn>
    <metstdv>FGDC-STD-001-1998</metstdv>
    <mettc>local time</mettc>
  </metainfo>
</metadata>